Items: 0Total: £0.00
View Basket
HEATING AND COOLING THERMOSTATS
DOUBLE THERMOSTATS AND THERMO-HYGROSTATS
Comprehensive ranges of heating and cooling thermostats, double
thermostats and thermo-hygrostats.
THV thermostats with normally open contacts for cooling devices
THR thermostats with normally closed contacts for heating devices
THRV and THVV double thermostats with dual contacts for heating
and cooling devices
ETUH electronic thermo-hygrostats for control of enclosure heaters
with high humidity or low temperature triggering and LED display
THR thermostat
All with mounting for 35mm DIN EN 50022 rail.
Three ranges of control devices for the accurate control of heat , condensation and humidity. The THV and THR thermostats operate
with a snap action, bimetallic, two pole contact set . The THRV and THVV double thermostats offer dual control in a single unit,
maximising space and simplifying wiring .The ETUH electronic thermo-hygrostat triggers for high humidity or low temperature and has
a LED status display.
Images are not to scale
THV thermostat
THRV double thermostat
ETUH thermo-hygrostat
Reference
Contact
Temperature
Load in A
Connections
Dimensions
function
range
250V/120V
H x W x D
Deg C
mm
THR01
Normally closed
-10/+50
10A / 15A
2 pole
68 x 34 x 38
THR02
Normally closed
0/+60
10A / 15A
2 pole
68 x 34 x 38
THR03
Normally closed
+20/+80
10A / 15A
2 pole
68 x 34 x 38
THV01
Normally open
-10/+50
10A / 15A
2 pole
68 x 34 x 38
THV02
Normally open
0/+60
10A / 15A
2 pole
68 x 34 x 38
THV03
Normally open
+20/+80
10A / 15A
2 pole
68 x 34 x 38
Reference
Contact set 1
Contact set
Load in A
Connections
Dimensions
Function &
2
250V/120V
H x W x D
Deg C
Function &
mm
Deg C
THRV13
NC –10/+50
NO +20/+80
10A / 15A
2 x 2 pole
68 x 53 x 38
THRV22
NC 0/+60
NO 0/+60
10A / 15A
2 x 2 pole
68 x 53 x 38
THVV22
NO 0/+60
N0 0/+60
10A / 15A
2 x 2 pole
68 x 53 x 38
Reference
Power
Temperature
Relative
Connections
Dimensions
Supply
range
humidity
H x W x D
50/60Hz
Deg C
% range
mm
ETUH11
120V
0/+60
30~90%
5 pole
68 x 53 x 38
ETUH22
230V
0/+60
30~90%
5 pole
68 x 53 x 38
Reference
NO Contacts
NO Contacts
NC Contacts
NC Contacts
AT 30V DC
at 250V AC
at 120V AC
at 250V AC
at 120V AC
ETUH11
10A
6A
3A
ETUH22
5A
3A
3A
Eastern Transformers and Equipment Ltd , Unit H1 Overland Business Park, Great Welnetham, Bury St Edmunds
Suffolk , England IP30 0UL. Tel 0044 (0) 1284 388033. Fax 386969. Web www.ete.co.uk . Email info@ete.co.uk