CUSTOM BUILT RANGE OF TOROIDAL TRANSFORMERS FROM 30VA TO 1.0KVA
OPEN TYPE OR FULLY ENCAPSULATED FROM 30VA TO 625VA
Custom built range of open type toroidal transformers
High efficiency and low radiated magnetic field
Low profile and high VA to weight ratio
Choice of disc fixing or potted centre fixing
TDO 100
A comprehensive range of open type, custom built toroidal transformers. All are designed and manufactured to customers
own requirements using top grade materials and employing the most advanced winding technology.
Standard designs are based around the sizes listed below but where units are required to fit into a specific area special
units can be produced.
Reference
VA
Maximum
Height
Fixing bolt
Approx.
Typical
Typical
Typical
rating
diameter
(diameter)
weight
temperature
efficiency
voltage
(mm)
(kg)
rise
regulation
TDO 30
30VA
75
35
M5
0.50
<60deg C
>85%
20%
TDO 50
50VA
85
45
M5
0.70
<60deg C
>85%
18%
TDO 100
100VA
100
35
M5
0.80
<60deg C
>90%
15%
TDO 150
150VA
100
45
M5
1.20
<60deg C
>90%
15%
TDO 200
200VA
110
55
M6
1.90
<55 deg C
>92%
12%
TDO 250
250VA
130
45
M6
2.20
<55 deg C
>92%
12%
TDO 300
300VA
120
55
M6
2.40
<55 deg C
>94%
12%
TDO 400
400VA
135
55
M6
2.80
<55 deg C
>94%
10%
TDO 500
500VA
150
60
M6
3.50
<55 deg C
>95%
10%
TDO 625
625VA
150
70
M8
4.00
<55 deg C
>95%
8%
TDO 1000
1KVA
170
75
M8
6.00
<55 deg C
>95%
7%
TDE 250
Custom built range of encapsulated toroidal transformers
Up to half the weight and width of conventional units
High efficiency and low radiated magnetic field
Centre bolt fixing
A comprehensive range of encapsulated, custom built, toroidal transformers. All are designed and manufactured to
customers own requirements using high grade polyamide moulded enclosures and a flame retardant polyester encapsula-
tion resin.Standard designs are based around the sizes listed below, but where units are required to fit into a specific area
special units can be produced.
Reference
VA
Maximum
Height
Fixing bolt Approx.
Typical
Typical
Typical
rating
diameter
(diameter)
weight
temperature
efficiency
voltage
(mm)
(kg)
rise
regulation
TDE 30
30VA
95
37
M5
0.70
<60deg C
>85%
20%
TDE 50
50VA
103
52
M5
1.00
<60deg C
>85%
18%
TDE 100
100VA
103
52
M5
1.10
<60deg C
>90%
15%
TDE 150
150VA
103
52
M5
1.40
<60deg C
>90%
15%
TDE 200
200VA
125
66
M6
2.10
<55 deg C
>92%
12%
TDE 250
250VA
140
65
M6
2.40
<55 deg C
>92%
12%
TDE 300
300VA
140
65
M6
2.60
<55 deg C
>94%
12%
TDE 400
400VA
140
65
M6
3.00
<55 deg C
>94%
10%
TDE 500
500VA
150
90
M6
3.80
<55 deg C
>95%
10%
TDE 625
625VA
150
90
M8
4.30
<55 deg C
>95%
8%
Eastern Transformers and Equipment Ltd , Unit H1 Overland Business Park, Great Welnetham, Bury St Edmunds